Vikram Kanigiri authored
TrustZone protection can be programmed by both memory and TrustZone address space controllers like DMC-500 and TZC-400. These peripherals share a similar programmer's view. Furthermore, it is possible to have multiple instances of each type of peripheral in a system resulting in multiple programmer's views. For example, on the TZC-400 each of the 4 filter units can be enabled or disabled for each region. There is a single set of registers to program the region attributes. On the DMC-500, each filter unit has its own programmer's view resulting in multiple sets of registers to program the region attributes. The layout of the registers is almost the same across all these variations. Hence the existing driver in `tzc400\tzc400.c` is refactored into the new driver in `tzc\tzc400.c`. The previous driver file is still maintained for compatibility and it is now deprecated. Change-Id: Ieabd0528e244582875bc7e65029a00517671216d
6b477063