Louis Mayencourt authored
In AArch32, execution of 2 instructions with opposite condition code might lead to either a data corruption or a CPU deadlock. Set the bit 12 of the Diagnostic Register to prevent this. Change-Id: I22b4f25fe933e2942fd785e411e7c0aa39d5c1f4 Signed-off-by: Louis Mayencourt <louis.mayencourt@arm.com>
25278eab