• Ambroise Vincent's avatar
    arm: Shorten the Firmware Update (FWU) process · 37b70031
    Ambroise Vincent authored
    
    
    The watchdog is configured with a default value of 256 seconds in order
    to implement the Trusted Board Boot Requirements.
    
    For the FVP and Juno platforms, the FWU process relies on a watchdog
    reset. In order to automate the test of FWU, the length of this process
    needs to be as short as possible. Instead of waiting for those 4 minutes
    to have a reset by the watchdog, tell it to reset immediately.
    
    There are no side effects as the value of the watchdog's load register
    resets to 0xFFFFFFFF.
    
    Tested on Juno.
    
    Change-Id: Ib1aea80ceddc18ff1e0813a5b98dd141ba8a3ff2
    Signed-off-by: default avatarAmbroise Vincent <ambroise.vincent@arm.com>
    37b70031
arm_err.c 299 Bytes