Soby Mathew authored
The CPU specific reset handlers no longer have the freedom of using any general purpose register because it is being invoked by the BL3-1 entry point in addition to BL1. The Cortex-A57 CPU specific reset handler was overwriting x20 register which was being used by the BL3-1 entry point to save the entry point information. This patch fixes this bug by reworking the register allocation in the Cortex-A57 reset handler to avoid using x20. The patch also explicitly mentions the register clobber list for each of the callee functions invoked by the reset handler Change-Id: I28fcff8e742aeed883eaec8f6c4ee2bd3fce30df
683f788f