Antonio Nino Diaz authored
Define the values as unsigned int or unsigned long long based on the actual size of the register. This prevents subtle issues caused by having a type that is too small. For example: #define OPTION_ENABLE 0x3 #define OPTION_SHIFT 32 uint64_t mask = OPTION_ENABLE << OPTION_SHIFT; Because OPTION_ENABLE fits in an int, the value is considered an int. This means that, after shifting it 32 places to the left, the final result is 0. The correct way to define the values is: #define OPTION_ENABLE ULL(0x3) #define OPTION_SHIFT U(32) In this case, the compiler is forced to use a 64 bit value from the start, so shifting it 32 places to the left results in the expected value. Change-Id: Ieaf2ffc2d8caa48c622db011f2aef549e713e019 Signed-off-by: Antonio Nino Diaz <antonio.ninodiaz@arm.com>
30399885