• Achin Gupta's avatar
    Fix handling of spurious interrupts in BL3_1 · 5717aae1
    Achin Gupta authored
    There are couple of issues with how the interrupt routing framework in BL3_1
    handles spurious interrupts.
    
    1. In the macro 'handle_interrupt_exception', if a spurious interrupt is
       detected by plat_ic_get_pending_interrupt_type(), then execution jumps to
       'interrupt_exit_\label'. This macro uses the el3_exit() function to return to
       the original exception level. el3_exit() attempts to restore the SPSR_EL3 and
       ELR_EL3 registers with values from the current CPU context. Since these
       registers were not saved in this code path, it programs stale values into
       these registers. This leads to unpredictable behaviour after the execution of
       the ERET instruction.
    
    2. When an interrupt is routed to EL3, it could be de-asserted before the
       GICC_HPPIR is read in plat_ic_get_pending_interrupt_type(). There could be
       another interrupt pending at the same time e.g. a non-secure interrupt. Its
       type will be returned instead of the original interrupt. This would result in
       a call to get_interrupt_type_handler(). The firmware will panic if the
       handler for this type of interrupt has not been registered.
    
    This patch fixes the first problem by saving SPSR_EL3 and ELR_EL3 early in the
    'handle_interrupt_exception' macro, instead of only doing so once the validity
    of the interrupt has been determined.
    
    The second problem is fixed by returning execution back to the lower exception
    level through the 'interrupt_exit_\label' label instead of treating it as an
    error condition. The 'interrupt_error_\label' label has been removed since it is
    no longer used.
    
    Fixes ARM-software/tf-issues#305
    
    Change-Id: I81c729a206d461084db501bb81b44dff435021e8
    5717aae1