- 07 Sep, 2018 3 commits
-
-
Icenowy Zheng authored
The AXP805 PMIC used with H6 is capable of shutting down the system. Add support for using it to shut down the system power. The original placeholder power off code is moved to A64 code, as it's still TODO to implement PMIC operations for A64. Signed-off-by: Icenowy Zheng <icenowy@aosc.io>
-
Icenowy Zheng authored
The OTT reference design of Allwinner H6 SoC uses an X-Powers AXP805 PMIC. Add initial code for it. Currently it's only detected. Signed-off-by: Icenowy Zheng <icenowy@aosc.io>
-
Icenowy Zheng authored
As the ATF may need to do some power initialization on Allwinner platform with AXP PMICs, call the PMIC setup code in BL31. Stub of PMIC setup code is added, to prevent undefined reference. Signed-off-by: Icenowy Zheng <icenowy@aosc.io>
-