1. 01 Jun, 2017 1 commit
    • Antonio Nino Diaz's avatar
      FWU: Check for overlaps when loading images · 128daee2
      Antonio Nino Diaz authored
      
      
      Added checks to FWU_SMC_IMAGE_COPY to prevent loading data into a
      memory region where another image data is already loaded.
      
      Without this check, if two images are configured to be loaded in
      overlapping memory regions, one of them can be loaded and
      authenticated and the copy function is still able to load data from
      the second image on top of the first one. Since the first image is
      still in authenticated state, it can be executed, which could lead to
      the execution of unauthenticated arbitrary code of the second image.
      
      Firmware update documentation updated.
      
      Change-Id: Ib6871e569794c8e610a5ea59fe162ff5dcec526c
      Signed-off-by: default avatarAntonio Nino Diaz <antonio.ninodiaz@arm.com>
      128daee2
  2. 20 Dec, 2016 1 commit
    • Sandrine Bailleux's avatar
      Improve FWU documentation · 34ba298e
      Sandrine Bailleux authored
      
      
       - Clarify the documentation of the 'FWU_SMC_IMAGE_COPY' SMC in the
         Firmware Update guide. Also extend the list of pre-conditions to
         include the additional input validation implemented by previous
         patches.
      
       - Improve documentation of bl1_plat_mem_check() in the porting
         guide. It now specifies that the generic FWU code protects
         bl1_plat_mem_check() from integer overflows resulting from
         the addition of the base address and size passed in arguments.
      
      Change-Id: I07b47a3778df7b9c089529b2dd2135707640a91c
      Signed-off-by: default avatarSandrine Bailleux <sandrine.bailleux@arm.com>
      34ba298e
  3. 12 Jan, 2016 1 commit
  4. 17 Dec, 2015 1 commit
    • Yatharth Kochar's avatar
      FWU: Add documentation for Firmware Update feature · 84a5d6d6
      Yatharth Kochar authored
      
      
      This patch adds design documentation for the Firmware Update (FWU)
      feature in `firmware-update.md`. It provides an overview of FWU,
      describes the BL1 SMC interface, and includes diagrams showing
      an example FWU boot flow and the FWU state machine.
      
      This patch also updates the existing TF documents where needed:
      
      *   `porting-guide.md`
      *   `user-guide.md`
      *   `firmware-design.md`
      *   `rt-svc-writers-guide.md`
      *   `trusted_board_boot.md`
      
      Change-Id: Ie6de31544429b18f01327bd763175e218299a4ce
      Co-Authored-By: default avatarDan Handley <dan.handley@arm.com>
      84a5d6d6