- 09 Sep, 2016 1 commit
-
-
Caesar Wang authored
We may need gpio pull mode later, so add this function. Besides fix a set pull mode bug, and save gpio clock gate, when operate the gpio, we will enable gpio clock, when finish gpio operate, restore gpio clock gate status. Change-Id: Ia1d602804f571a17f5ddc499908663b968b02974
-
- 27 May, 2016 1 commit
-
-
Caesar Wang authored
There are 5 groups of GPIO (GPIO0~GPIO4), totally have 122 GPIOs on rk3399 platform. The pull direction(pullup or pulldown) for all of GPIOs are software-programmable. At the moment, we add the gpio basic driver since reset or power off the devices from gpio configuration for BL31.
-