zynqmp: pm: Correct WDT clock database
Siva Durga Prasad Paladugu authored
WDT used by APU is FPD_WDT. FPD WDT clock is controlled by
FPD_SLCR.WDT_CLK_SEL register. Correct the same in WDT clock
database.

As per FPD_SLCR.WDT_CLK_SEL register, there can be only two
parents of WDT clock not three. Fix the same by correcting it's
parents in clock database.
Signed-off-by: default avatarTejas Patel <tejas.patel@xilinx.com>
Signed-off-by: default avatarSiva Durga Prasad Paladugu <siva.durga.paladugu@xilinx.com>
Acked-by: default avatarJolly Shah <jolly.shah@xilinx.com>
96cd17f4