1. 21 Jun, 2018 6 commits
  2. 20 Jun, 2018 4 commits
  3. 19 Jun, 2018 25 commits
  4. 18 Jun, 2018 3 commits
  5. 15 Jun, 2018 2 commits
    • Antonio Nino Diaz's avatar
      SPM: Refactor entry and exit of the SP · 14fcc6e1
      Antonio Nino Diaz authored
      
      
      Only use synchronous calls to enter the Secure Partition in order to
      simplify the SMC handling code.
      
      Change-Id: Ia501a045585ee0836b9151141ad3bd11d0971be2
      Signed-off-by: default avatarAntonio Nino Diaz <antonio.ninodiaz@arm.com>
      14fcc6e1
    • John Tsichritzis's avatar
      Panic in BL1 when TB_FW_CONFIG is invalid · 355e0967
      John Tsichritzis authored
      
      
      In Arm platforms, when using dynamic configuration, the necessary
      parameters are made available as a DTB. The DTB is loaded by BL1 and,
      later on, is parsed by BL1, BL2 or even both, depending on when
      information from the DTB is needed.
      
      When the DTB is going to be parsed, it must be validated first, to
      ensure that it is properly structured. If an invalid DTB is detected
      then:
        - BL1 prints a diagnostic but allows execution to continue,
        - BL2 prints a diagnostic and panics.
      
      Now the behaviour of BL1 is changed so for it also to panic. Thus, the
      behaviour of BL1 and BL2 is now similar.
      
      Keep in mind that if BL1 only loads the DTB but it doesn't need to
      read/write it, then it doesn't validate it. The validation is done only
      when the DTB is actually going to be accessed.
      
      Change-Id: Idcae6092e6dbeab7248dd5e041d6cbb7784fe410
      Signed-off-by: default avatarJohn Tsichritzis <john.tsichritzis@arm.com>
      355e0967