- 22 Jun, 2018 1 commit
-
-
Jeenu Viswambharan authored
commit 2ccfcb2e ("SDEI: Determine client EL from NS context's SCR_EL3") intended to read from SCR_EL3, but wrongly read from SPSR_EL3 instead. This patch fixes that. Change-Id: I8ffea39cc98ef59cb8e7a4c6ef4cb12011c58536 Signed-off-by: Jeenu Viswambharan <jeenu.viswambharan@arm.com>
-
- 21 Jun, 2018 3 commits
-
-
Jeenu Viswambharan authored
SDEI event dispatches currently only sets up the Non-secure context before returning to the caller. The actual dispatch only happens upon exiting EL3 next time. However, for various error handling scenarios, it's beneficial to have the dispatch happen synchronously. I.e. when receiving SDEI interrupt, or for a successful sdei_dispatch_event() call, the event handler is executed; and upon the event completion, dispatcher execution resumes after the point of dispatch. The jump primitives introduced in the earlier patch facilitates this feature. With this patch: - SDEI interrupts and calls to sdei_dispatch_event prepares the NS context for event dispatch, then sets a jump point, and immediately exits EL3. This results in the client handler executing in Non-secure. - When the SDEI client completes the dispatched event, the SDEI dispatcher does a longjmp to the jump pointer created earlier. For the caller of the sdei_dispatch_event() in particular, this would appear as if call returned successfully. The dynamic workaround for CVE_2018_3639 is slightly shifted around as part of related minor refactoring. It doesn't affect the workaround functionality. Documentation updated. NOTE: This breaks the semantics of the explicit dispatch API, and any exiting usages should be carefully reviewed. Change-Id: Ib9c876d27ea2af7fb22de49832e55a0da83da3f9 Signed-off-by: Jeenu Viswambharan <jeenu.viswambharan@arm.com>
-
Jeenu Viswambharan authored
Currently, the dispatcher reads from SCR_EL3 register directly to determine the EL of SDEI client. This is with the assumption that SCR_EL3 is not modified throughout. However, with RAS work flows, it's possible that SCR_EL3 register contains values corresponding to Secure world, and therefore EL determination can go wrong. To mitigate this, always read the register from the saved Non-secure context. Change-Id: Ic85e4021deb18eb58757f676f9a001174998543a Signed-off-by: Jeenu Viswambharan <jeenu.viswambharan@arm.com>
-
Jeenu Viswambharan authored
The current macros only allow to define dynamic and statically-bound SDEI events. However, there ought be a mechanism to define SDEI events that are explicitly dispatched; i.e., events that are dispatched as a result of a previous secure interrupt or other exception This patch introduces SDEI_EXPLICIT_EVENT() macro to define an explicit event. They must be placed under private mappings. Only the priority flags are allowed to be additionally specified. Documentation updated. Change-Id: I2e12f5571381195d6234c9dfbd5904608ad41db3 Signed-off-by: Jeenu Viswambharan <jeenu.viswambharan@arm.com>
-
- 13 Nov, 2017 1 commit
-
-
Jeenu Viswambharan authored
The implementation currently supports only interrupt-based SDEI events, and supports all interfaces as defined by SDEI specification version 1.0 [1]. Introduce the build option SDEI_SUPPORT to include SDEI dispatcher in BL31. Update user guide and porting guide. SDEI documentation to follow. [1] http://infocenter.arm.com/help/topic/com.arm.doc.den0054a/ARM_DEN0054A_Software_Delegated_Exception_Interface.pdf Change-Id: I758b733084e4ea3b27ac77d0259705565842241a Co-authored-by: Yousuf A <yousuf.sait@arm.com> Signed-off-by: Jeenu Viswambharan <jeenu.viswambharan@arm.com>
-