1. 23 Apr, 2021 3 commits
  2. 21 Apr, 2021 3 commits
  3. 20 Apr, 2021 23 commits
  4. 15 Apr, 2021 1 commit
  5. 14 Apr, 2021 1 commit
  6. 09 Apr, 2021 1 commit
    • Manish Pandey's avatar
      plat/arm: don't provide NT_FW_CONFIG when booting hafnium · 2b6fc535
      Manish Pandey authored
      
      
      NT_FW_CONFIG file is meant to be passed from BL31 to be consumed by
      BL33, fvp platforms use this to pass measured boot configuration and
      the x0 register is used to pass the base address of it.
      
      In case of hafnium used as hypervisor in normal world, hypervisor
      manifest is expected to be passed from BL31 and its base address is
      passed in x0 register.
      
      As only one of NT_FW_CONFIG or hypervisor manifest base address can be
      passed in x0 register and also measured boot is not required for SPM so
      disable passing NT_FW_CONFIG.
      Signed-off-by: default avatarManish Pandey <manish.pandey2@arm.com>
      Change-Id: Ifad9d3658f55ba7d70f468a88997d5272339e53e
      2b6fc535
  7. 08 Apr, 2021 3 commits
  8. 06 Apr, 2021 2 commits
    • Heyi Guo's avatar
      plat/arm/arm_image_load: refine plat_add_sp_images_load_info · abe6ce1d
      Heyi Guo authored
      
      
      Refine the function plat_add_sp_images_load_info() by saving the
      previous node and only setting its next link when the current node is
      valid. This can reduce the check for the next node and simply the
      total logic.
      Signed-off-by: default avatarHeyi Guo <guoheyi@linux.alibaba.com>
      Change-Id: I4061428bf49ef0c3816ac22aaeb2e50315531f88
      abe6ce1d
    • Heyi Guo's avatar
      plat/arm/arm_image_load: fix bug of overriding the last node · 47fe4c4f
      Heyi Guo authored
      
      
      The traverse flow in function plat_add_sp_images_load_info() will find
      the last node in the main load info list, with its
      next_load_info==NULL. However this node is still useful and should not
      be overridden with SP node info.
      
      The bug will cause below error on RDN2 for spmd enabled:
      
      ERROR:   Invalid NT_FW_CONFIG DTB passed
      
      Fix the bug by only setting the next_load_info of the last node in the
      original main node list.
      Signed-off-by: default avatarHeyi Guo <guoheyi@linux.alibaba.com>
      Change-Id: Icaee5da1f2d53b29fdd6085a8cc507446186fd57
      47fe4c4f
  9. 01 Apr, 2021 2 commits